Eco 50

Description

The twin wall "Eco 50" system is composed of some rigid modular elements with bright finishing BA or Copper. All items are manufactured with inner wall made in stainless steel AISI 316L (1.4404) thickness 0,5 mm. The outer wall is in stainless steel AISI 304 compliant with the standards required by the CE marking, according to the rule EN 1856/1. The insulation is made of high-density mineral wool, 50 mm thick: a pressed block of insulation material for the linear elements, and a high-density insufflated material for the connection elements and accessories, by using state-of-the-art machinery. The inner wall elements have a male-female "glass slip on coupling" with a triple-lip seal seat. A mechanical seal joint is used for the external wall through the use of the locking band.

Applications

  • Ducts,
  • connecting flue pipes,
  • metal chimneys for the evacuation of dry or wet smokes,
  • under pressure or depression,
  • from the appliance to the atmosphere

Fuels and product use suitable for

Application of the product

Available diameters

100/200 - 130/230 - 150/250 - 180/280 - 200/300 -250/350 -350/450
Upon request "big diameter" variation 400/500 - 450/550 - 500/600 - 600/700 - 700/800 - 800/900

Gaskets

Included and installed on D.100/200. It is upon request for all further diameters.

Designation of the product

Product marking according to the European rule: CE 0476 EN 1856-1.

Logo Kiwa

Eco 50

Description of the product

A: Outer wall Stainless steel AISI 304 th.5/10 – Copper th.5/10
B: Inner wall Stainless steel AISI 316L (1.4404) th. 5/10 (6/10 – 8/10 upon request)
C: High-density insulation material Min. 90Kg/m3 – th.50mm
D: Silicone gasket from (-90°C to +200°C)

Canna Fumaria Eco 50

Use with gasket

EN 1856/1 09 : T200 – P1 – W – V2 – L50050 – O (xx)
CHIMNEY SYSTEM EN 1856/1: RULE OF REFERENCE
T200: Class of temperature (200°C)
P1: Class of pressure (P1: 200Pa)
W: Resistance and condensation tightness (W: Wet)
V2: Resistance to corrosion (Yes)
L50: Specification of the material (stainless steel 1.4404 AISI 316L)
050 o 060: Thickness of the material (050 thickness 5/10) – 060 (thickness 6/10)
O: Resistance to soot fire (O: no – G: yes)
(xx): Distance from combustible materials in mm
Distance in standard working conditions: (10): from D.100 to D.300 – (15): from D.301 to D. 450 – (20): from D.451 to D.600 – (40): bigger than D.600

Use without gasket

EN 1856/1 09 : T600 – N1 – D – V2 – L50050 – G (zz)
T600: Class of temperature (600°C)
N1: Class of pressure (N1: 40Pa)
D: Resistance and condensation tightness (D: Dry)
V2: Resistance to corrosion (Yes)
L50: Specification of the material (stainless steel 1.4404 AISI 316L)
050: Thickness of the material (050 thickness 5/10) – 060 (thickness 6/10)
G: Resistance to soot fire (O: no – G: yes)
(zzM): Distance from combustible materials in mm – M=measured
Distance in conditions of soot fire: (30M): from D.100 to D.300 – (45M): from D.301 to D. 450 – (60M): from D.451 to D.600 – (120M): bigger than D.600